Hello i m using standard installation with t harnesses, i cannot find a specific guide of evo-all + cm7000,
https://fortin.ca/download/87591/evo-all_ig_thr_bi_toy6-chr_2019_pts-hybrid_euro_a_87591.pdf
service number : 001A06753794
cm7000 has the connector nr.3 (Gray) with 6 pin, i connected the ground and the +12v in order to give power to the unit (i thought the voltage from the data port was enough, but it wasn't)
My question is on the pin nr. 5, guide says :
Pin 5 Green: Ignition 12V positive (+) output and input. This wire must be connected to the vehicles’
ignition for remote start and valet / remote programming. The proper wire will test 0V with the key in
the off position, 12 V (+) while the key is in the on position and 12V (+) during crank. Note: this is a
low current ignition output and will not support more than 1A (+)
Do i have to connect this wire to acc of my vehicle only for remote programming or it should be connected as permament? The evo all should give info of ACC ON to the cm7000 so this connection can be avoided right?
P.s I see the both cm 7000 and evo all are remote starter but i have to use the evo all as remote starter not the cm7000, so when i launch from the compustar remote the remote start routine how it works?