Hey all, working on an 07 F-150 and have an evo-one almost completely setup and trying to get my starter kill relay to energize when alarm is armed. The dark blue (A8) starter kill wire will not apply a ground when you arm the evo-one. 32.4 is enabled along with 10.1. I've tested the relay is wired correctly and works if you take 86 straight to ground. anything i'm missing in the programming?
Also: function 9.1 is enabled for active alarm.
i have relay wired as this:
85 - Ign 12V+
86 - Dk blue (a8) wire from evo module
87a - key side of starter wire at ignition switch
30 - harness (truck side) of starter wire.